ZUMBACH Spark Tester

Download

Dielectric Testing with the Spark Test Principle (Dry Test):

In-line fault testing on single conductors and jackets during the extrusion or rewinding process has become standard procedure today. ZUMBACH Spark Testers can be used to test the most diverse range of cable products as per international standards, like EN, BS, CEN/CENELEC, CSA, NEMA, UL, UTE, VDE, and so on, thanks to the multitude of electrodes, test voltages, and frequencies available. Data ports allow for easy integration with quality control systems (e.g. USYS).

 

Important Features:

  • Robust, durable
  • Accurate, repeatable
  • In compliance with standards
  • Selective
  • Optimum operation
  • Available in all sizes

CALIBRATOR SP - Vital for Quality Assurance and ISO 9000

  • Used for periodic verification and calibration of AC, AC-HF, DC, and Impulse Spark Testers of any model and any make. Complies with all Spark Tester standards.
  • Test voltage and short circuit current measurement can be certified.
CALIBRATOR
 

Important Features:

  • Measures all existing categories of test voltages
  • Measures test voltage, short circuit current, frequency, fault sensitivity
  • Easily accessible on the line, thanks to compact and ergonomic design

Fault Detection on Plastic Pipe

Thanks to a special AST high-voltage test instrument, rigorous quality requirements, as the apply to floor heating pipes, chemical pipes, gas pipes, and others, can be guaranteed without a problem. The instrument detects the smallest, practically invisible faults, like pinholes and microscopic cracks.

  • Diameter Range: 14...25 mm (.55...1 in.)
  • Wall Thickness: up to 2.5 mm (.1 in.)
  • Test Voltages: 0...25 kV AC
 
AST In-Line

 

General Data

Thousands of ZUMBACH Spark Testers have been detecting blank spots and faults in processes like:

System Configuration
Insulating Lines

System Configuration
Jacketing Lines

System Configuration
Rewind Lines

System Configuration
Assembling


Electrode Units

  Alternate Current Test Voltage [kV] Max Diameter
AST L Standard 50 / 60 Hz 15, 25 50, 90 mm (2, 3.5 in.)
AST L Heavy Duty 50 / 60 Hz 15, 25, 40 130, 150, 200 mm (5, 6, 8 in.)
AST-HF 3 kHz 15 12 mm (.5 in.)
  Direct Current    
SPARKMASTER DST Direct Current 1 ... 15 10, 12, 30 mm (.4, .5, 1.2 in.)
  Impulse    
IST Impulse 15, 25 10, 30 mm (.4, 1.2 in.)

 

AST L Heavy Duty     AST L Standard

AST

AST-HF

SPARKMASTER DST dummy SPARKMASTER DSTdummySPARKMASTER DST

SPARKMASTER DST


Control and Display

Several operating units may be connected to the various electrodes for display of the test voltage, number of faults, alarms, etc. All spark testing systems can be interfaced directly or via existing data port to a central processor, PLC or to a USYS processor and, therefore, can be controlled remotely. AST-HF and SPARKMASTER DST electrode units can also be controlled directly through PROFIBUS DP or serial RS connections. An additional control unit (RI) offers this option for the AST L Spark Tester as well.

AST

19" Versions:
AST L-19A, SP 30
AST L-19RI-SP, IST

Computer-Interface:
CI SP/CMK
CI SP/DP
CI SP/RS

 

Bench Top Models:
SP 30

 